Vulcanizing Presses

Electronics control cabinet with data recording

• Exact temperature measurement inside of heating plates via double PT 100, display on touch panel 

• Enclosed software for the composition of a vulcanization protocol as a PDF document 

• In case of electronic control failure switch to manual operation mode

• Monitoring of differences between the single heating circuits +/- 2,5 K • USB interface for data transfer 

• Optical signal shows end of vulcanizing time 

• Optionally equipped with WLAN module for realtime display on MS Windows notebook or tablet 

• Illuminated control panel 

• Protection class IP 44 • Menu navigation (DE/EN/ES/FR)